简要描述:Constant pressure water make-up function: When the system pressure in the closed air conditioning system rises due to temperature or other factors, the overflow solenoid valve of the constant pressure equipment opens, releasing the cold (hot) media water from the closed system into the atmospheric pressure tank, lowering the system pressure to the normal set value; When the pressure of the closed air conditioning system drops due to temperature or other factors, the constant pressure equipment activates the booster pump to replenish the cold (hot) agent water from the atmospheric pressure tank into the system to maintain normal pressure. Exhaust function: System water enters the atmospheric pressure diaphragm
产品型号
厂商性质
更新时间
浏览次数
产品分类
Constant Pressure Water Replenishment Function
When the system pressure increases due to temperature or other factors in the closed air conditioning system, the overflow solenoid valve of the constant pressure equipment opens, allowing the cold (heating) medium water from the closed system to be released into the atmospheric pressure tank, lowering the system pressure to the normal set value; When the pressure of the closed air conditioning system drops due to temperature or other factors, the constant pressure equipment activates the booster pump to replenish the cold (hot) agent water from the atmospheric pressure tank into the system to maintain normal pressure.
Exhaust function:
After the system water enters the atmospheric pressure diaphragm tank, the gas and water are separated. The separated gas is discharged through the exhaust valve, and the discharged water is injected into the system by a water pump, repeating the cycle. This effectively solves the air problem in the piping system.
Device features
Precise pressure determination function: can regulate the volume expansion and contraction caused by temperature changes in the water system, keeping the pressure at the water system set point constant; The pressure sensor detects system pressure in real time and outputs signals to the control unit, thereby precisely stabilizing system pressure and ensuring the stable operation of the water system. The constant pressure value can be set on-site according to the requirements of the air conditioning water system. ± deviation can be freely set. When the deviation is very small and the pump starts repeatedly, a pump delay function can be set to achieve the required constant pressure in one
go
Automatic water replenishment function: Water lost due to exhaust gases and system drips can be monitored in real time by the control unit. If it falls below the set value, a constant pressure pump automatically draws water from the tank or municipal pipeline network to replenish it. The control unit monitors in real time and promptly replenishes system pressure.
Automatic drainage function: The water system expands volume due to temperature changes. When the expansion becomes unbearable for the system and tank, the pressure relief valve automatically opens to ensure system safety. When the pressure relief valve malfunctions and the pressure reaches the maximum load capacity of the mechanical valve, the mechanical valve automatically opens. The control unit sends out an alarm signal. When the pressure relief valve repeatedly releases pressure, a pressure relief delay can also be set to increase equipment operational stability.